Drop-In/Push Up Plastic Loft Access Door
Drop-In/Push Up Plastic Loft Access Door
Insulated drop-in/push up loft access hatch and frame to provide simple, easy access through ceiling into the loft space.
Choice of insulation U value performances of 0.82, 0.35 and 0.25W/m2k.
Ideal solution for applications where floor space is at a premium.
Designed to fit between 38mm thick trussed rafters or ceiling joists spaced 600mm centres which provide a clear joist opening width of 562mm.
Clean simple design that will blend well with most surrounding decors, with a slightly textured finish that can be painted if required.
Tested and certified by BRE as meeting Building Regulation Part L’s reasonable air leakage requirements of <10m3/(h.m2) at a pressure differential of 50Pa and BS5250:2011.
Featuring integral anti-draught, vapour and condensation migration seal and discrete easy twist catches to secure the door panel and prevent uplift.
0.5m loft door operating pole, specific to this range, available.
Not suitable for use with telescopic loft ladders.
Features & Benefits
Purpose made product saves time and money compared with traditional joiner-made timber loft access doors
Meets the requirements of Part L’s air leakage requirements and BS5250:2011
Excellent aesthetic appearance
Paintable if required
Factory finished and ready to fit straight from the box
Insulated door panel
Integral anti-draught and condensation migration seal
Two easy twist operated catches prevents uplift
Applications
Residential new build and replacement projects
Technical Information
Ozone depletion potential (ODP) of zero
Global warming potential (GWP) of less than 5
Contains polystyrene insulation with a thermal conductivity of 0.038W/mk, therefore a correction U value of 0.0004W/m2k should be calculated to the proposed U value figures for a ceiling (U value for a ceiling, not to exceed 0.16W/m2k)
The insulation material featured in this range do not use, contain or produce Urea Formaldehyde, CFC’s or indeed any of the so called soft CFC’s, ie HCFC’s
Meets the air leakage requirements of Building Regulation Approved Documents L1A & L2A (20130 editions) ‘Conservation of fuel and power’ of <10m3/(h.m2) at a pressure differential of 50Pa
Complies with BS5250 2011 the Code of Practice for control of condensation in buildings
Installation Advice
Designed to fit between 38mm thick trussed rafters or ceiling joists spaced 600mm centres to provide a clear joist opening width of 562mm
If the roof design does not provide this joist opening width, a suitable opening must be formed
Trimmers must be installed across the ends of a frame; these should be spaced to give a clear opening length of 665mm
The frame fixes ten screws (supplied) - three through each side and two through each end
Do not over tighten the fixing screws as this could distort the screws
Fit the loft access door after the ceiling has been plaster boarded and skimmed
The frame must be a good fit into the trimmed opening, never force it into an opening that is too small, if the opening is too large use packers to ensure a good fit
Drop-In/Push Up Plastic Loft Access Door (P1168)
- Brand: Timloc
- Product Code:P1168
- Download Product Information: Login For Download
Tags: timloc, drop-in, push-up, plastic, loft, access, door, hatch drop-in/push, hatches, p1168